logo
Gefunden 90 Produkte für "

overhead line conductor

"
Qualität Optimale Leistungsübertragung mit 61 Leitungen ACSR-Leiter in Bare-Conductor-Modell Fabrik

Optimale Leistungsübertragung mit 61 Leitungen ACSR-Leiter in Bare-Conductor-Modell

Product Description: The Bare Conductor ACSR is a high-quality product designed for overhead power transmission lines. Made from Aluminum Conductor Steel Reinforced (ACSR) material, this bare conductor offers excellent strength and durability, making it ideal for a wide range of applications. With a ...

Qualität ACSR Wolf Blankdraht für Freileitungen Fabrik

ACSR Wolf Blankdraht für Freileitungen

ACSR Wolf Bare Conductor for Overhead Transmission Lines APPLICATION ACSR Wolf Bare Conductor‌ is primarily used in ‌overhead power transmission lines‌ for efficient electricity distribution. Its design combines aluminum layers for conductivity and a galvanized steel core for mechanical strength, ...

Qualität Blank-Aluminiumleiter Freileitungen ACSR-Kabel Lynx Aluminiumleiter Stahlverstärktes Kabel Fabrik

Blank-Aluminiumleiter Freileitungen ACSR-Kabel Lynx Aluminiumleiter Stahlverstärktes Kabel

18kV SWA Armoured Aluminium Alloy Conductor Copper Tape Screened Cable for Underground Power Distribution Application The Bare Aluminum Conductor Steel Reinforced (ACSR) Lynx cable is widely used in overhead power transmission and distribution systems due to its excellent balance of strength, ...

Qualität 15kV 35kV ACSR Leiter ABC Aerial Bundled Kabel Mittelspannung Oberleitungskabel Fabrik

15kV 35kV ACSR Leiter ABC Aerial Bundled Kabel Mittelspannung Oberleitungskabel

15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable APPLICATION 1 phase:t o supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 1000 volts or lower at a conductor temperature of 75℃ maximum. 2 phase: t o ...

Qualität ACSRC Selbsttragende, aus der Luft getragenen ABC-Leistungskabel IEC228 IEC208 IEC502 für Oberleitungen Fabrik

ACSRC Selbsttragende, aus der Luft getragenen ABC-Leistungskabel IEC228 IEC208 IEC502 für Oberleitungen

ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 For Overhead Distribution Line APPLICATION 1 phase:t o supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 1000 volts or lower at a conductor temperature of 75...

Qualität AAC  AAAC  ACSR Aluminium Conductor Cable 16-1120mm Power Distribution Conductors Fabrik

AAC AAAC ACSR Aluminium Conductor Cable 16-1120mm Power Distribution Conductors

AAC, AAAC, ACSR Aluminium Conductor Cable 16-1120mm Power Distribution Conductors APPLICATION Overhead Power Transmission and Distribution Coastal and Corrosive Environments Long-Span Installations Renewable Energy Projects CONSUTRUCTION SPECIFICATION ABOUT US PROJECTS WHY US PARTNER FAQ 1.What is ...

Qualität 6201 AAAC Bare Conductor ASTM B 399 155.4MCM 559.5MCM for Overhead Distribution Fabrik

6201 AAAC Bare Conductor ASTM B 399 155.4MCM 559.5MCM for Overhead Distribution

6201 AAAC Bare Conductor ASTM B 399 155.4MCM 559.5MCM for Overhead Distribution APPLICATION The ‌6201 AAAC (All Aluminum Alloy Conductor)‌ bare conductor is primarily used in overhead power transmission lines due to its high conductivity, mechanical strength, and corrosion resistance‌ C ONSTRUCTION ...

Qualität Übergeordnete Kabel 3*70 Alu NFC 33-209 ABC Kabel Fabrik

Übergeordnete Kabel 3*70 Alu NFC 33-209 ABC Kabel

Overhead Aerial Bundled Cable 3*70 Alu NFC 33-209 ABC Cable Deatils Phase Conductor : Aluminium Conductor Neutral Conductor : AAAC(All Aluminium Alloy Conductor)Insulation : XLPE/PERated Voltage : 0.6/1KVCores : 1,2,3,4,5,2+1, 3+1 ,3+2, 4+1, 4+2 CoresOther Standards: ASTM/ BS 7870-5/ IEC 60502/AS...

Qualität Wärmebeständig 750 MCM AAAC Aluminiumlegierung Leiter für Oberleitungen Fabrik

Wärmebeständig 750 MCM AAAC Aluminiumlegierung Leiter für Oberleitungen

Thermal Resistant 750 MCM AAAC Aluminum Alloy Conductor Overhead Power Lines Application Used for overhead power lines, ground wires, steel stay wires Applicable standards: Aluminum alloy conductor (AAAC) are produced according to ASTM B-399, BS EN-50182, AS/NZS 1531, DIN 48201, CSA 61089, IEC 61089...