logo
Trouvé 96 produits pour "

underground armored cable

"
Qualité Cable blindé AWA à noyau unique à tension moyenne jusqu'à 36 kV pour les réseaux électriques urbains Fabrique

Cable blindé AWA à noyau unique à tension moyenne jusqu'à 36 kV pour les réseaux électriques urbains

Single Core AWA Armoured Cable Medium Voltage up to 36kV for Urban Power Grids APPLICATION Single Core AWA (Aluminium Wire Armoured) Medium Voltage Cable is engineered with a lightweight aluminium wire armour layer, delivering excellent mechanical protection, corrosion resistance and flexible installation performance. Designed for medium voltage systems typically ranging from 3.6/6 kV to 26/35 kV , it is widely deployed in the following critical scenarios: Urban power grids

Qualité Cable électrique haute tension HV 64/110 kV 1X630 mm CEI 60840 CEI 62067 Fabrique

Cable électrique haute tension HV 64/110 kV 1X630 mm CEI 60840 CEI 62067

64/110kV HV High Voltage Power Cable 1X630mm IEC 60840 IEC 62067 APPLICATION ‌Urban Power Distribution: ‌ Transmits electricity efficiently in densely populated areas. ‌Industrial Power Supply: ‌ Supports large-scale industrial facilities with high energy demands. ‌Renewable Energy Integration: ‌ Connects wind/solar farms to the grid. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield

Qualité Cable d'alimentation blindé ignifuge CU/XLPE/AWA/SWA/PE pour la transmission de puissance Fabrique

Cable d'alimentation blindé ignifuge CU/XLPE/AWA/SWA/PE pour la transmission de puissance

Flame Retardant Armoured Power Cable CU/XLPE/AWA/SWA/PE for Power Transmission APPLICATION Flame Retardant Armoured Power Cable CU/XLPE/AWA/SWA/PE for Power Transmission‌ is a high-performance cable designed for safe and reliable power transmission in demanding environments CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler ( options ): Polypropylene mesh tear rope or flame-retardant filling

Qualité Résistant au feu STA câble blindé Multi-Core câble de commande en PVC enveloppé Fabrique

Résistant au feu STA câble blindé Multi-Core câble de commande en PVC enveloppé

Steel Tape Armoured STA Fire Resistant Flame Retardant PVC Sheathed Control Cable Application Suitable for indoor use, fixed installations, in public areas such as hospitals, hotels, shopping malls, airports, underground railway networks, tunnels, communication centres, and, in general, all places where it is required a high degree of protection of persons and assets or/and with a large number of people and electrical/electronic equipment. Characteristics Rated power

Qualité Cable de conducteur en aluminium à bande de cuivre Shield 3.6 KV 6kV Voltage moyen personnalisé Fabrique

Cable de conducteur en aluminium à bande de cuivre Shield 3.6 KV 6kV Voltage moyen personnalisé

Copper Tape Shield Aluminium Alloy Conductor Cable 3.6/6kV Medium Voltage Application Direct Burial Installation‌: Designed for underground installation with steel tape or steel wire armor, providing superior resistance to mechanical pressure, rodent damage, and insect intrusion in soil environments. Industrial Infrastructure‌: Widely used in cable trenches, trays, and conduits within factories, refineries, and mining facilities, where high mechanical stress and electromagnet

Qualité OEM câble d'alimentation XLPE à un seul noyau et à trois noyaux Cu XLPE PVC SWA câble à tension moyenne Fabrique

OEM câble d'alimentation XLPE à un seul noyau et à trois noyaux Cu XLPE PVC SWA câble à tension moyenne

Single Core Three Core XLPE Insulated Power Cable Cu/XLPE/PVC/SWA Medium Voltage Cable Application XLPE (Cross-Linked Polyethylene) insulated cables are widely used in power transmission and distribution systems due to their high thermal resistance, mechanical strength, and excellent electrical insulation properties. They are commonly applied in medium- to high-voltage networks, underground and submarine installations, industrial plants, and commercial or residential

Qualité Cable d'alimentation MV à tension moyenne 8.7/15 kV XLPE Fabrique

Cable d'alimentation MV à tension moyenne 8.7/15 kV XLPE

Copper Conductor Medium Voltage Cable 8.7/15kV Cu/XLPE/PVC/SWA Construction Conductor: Circular compacted stranded Copper or aluminium Conductor screen: Extruded semi-conductive compound Insulation: XLPE Insulation screen: Extruded semi-conductive compound Metallic screen: Copper Wire Binder tape: non-hygroscopic material Inner covering(bedding): PVC Metallic armor: Galvanized steel tape Application Medium-voltage cables (typically rated between 1 kV and 35 kV) are extensivel

Qualité Câble d'alimentation moyenne tension 35 kV à conducteur en aluminium avec isolation XLPE et armure en ruban d'acier pour la transmission d'énergie Fabrique

Câble d'alimentation moyenne tension 35 kV à conducteur en aluminium avec isolation XLPE et armure en ruban d'acier pour la transmission d'énergie

35kV MV Aluminium Alloy Conductor Power Cable AL/XLPE/STA/PVC for Power Transmission Application This 35kV medium-voltage aluminium alloy conductor cable enables efficient, cost-effective power transmission, featuring XLPE insulation for superior dielectric strength, steel tape armoring for robust mechanical protection, and PVC sheathing for moisture and corrosion resistance. Ideal for urban grid upgrades, industrial park power supply, rural long-distance electrification,

Qualité Câble d'alimentation MT résistant au feu CU/XLPE/CTS/CWS/SWA/FR-PVC pour ligne sortante de centrale électrique Fabrique

Câble d'alimentation MT résistant au feu CU/XLPE/CTS/CWS/SWA/FR-PVC pour ligne sortante de centrale électrique

Fire Resistant MV Power Cable CU/XLPE/CTS/CWS/SWA/FR-PVC Cable for Outgoing Line of Power Station Application This product is suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. Construction Conductor: Tightly press round conductor Conductor Screen: Semi-conductive shield Insulation:XLPE Insulation shield: Semi-conductive shield