pvc insulated industrial cables
"
Cable halogène à faible émission de fumée, ignifuge, 0,6 kV 1 kV XLPE isolé YJY23
Flame Retardant Low Smoke Zero Halogen Cable 0.6/1kV XLPE Insulated YJY23 Application Industrial Factory Power Distribution Systems High-Risk Buildings Transportation Infrastructure Hazardous Environments Emergency Systems Construction Conductor :Class 2 stranded copper conductor Insulation :XLPE (Cross-Linked Polyethylene) Bedding :LSZH (Low Smoke Zero Halogen) Armour :SWA (Steel Wire Armour) Sheath :LSZH (Low Smoke Zero Halogen) Advantage Composite high
0.6/1.0KV câble solaire basse tension XLPO enveloppe 1 câble d'alimentation LV
0.6/1.0KV Low Voltage Cable Solar Cable XLPO Sheath Sustainable Energy PV1-F Applications Solar Photovoltaic (PV) Systems – Connects solar panels to inverters (DC side). Renewable Energy Installations – Wind turbines, battery storage systems. Outdoor Wiring – Suitable for exposed or buried (with conduit) installations. Industrial & Agricultural Use – Flexible routing in harsh environments. Structure Conductor: Tinned copper (single-core, Class 5 flexible stranded wire).
0.6/1kV câble d'alimentation résistant au feu CU/ XLPE/ PVC 07V-Z CEI 60332-3C CEI 60331
0.6/1kV Fire Resistant Power Cable CU/ XLPE/ PVC 07V-Z IEC 60332-3C IEC 60331 APPLICATION This product is suitable for use in line filling circuits rated voltage not exceeding 0.6/1kV for power transmission and distribution CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler ( options ): Polypropylene mesh tear rope or flame-retardant filling Outer sheath: Polyvinyl chloride (PVC) CHARA C
Cable blindé en acier galvanisé XLPE Insulté NYR2Y NAYR2Y
Underground Galvanized Steel Wire Armoured Electrical Cable XLPE Insulted NYR2Y NAYR2Y Application Used for electricity supply in low voltage installation system, they are suitable for installation in indoors and outdoors, in cable ducts, underground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum
110 kV câble à haute tension à noyau unique 1000 mm2 600 mm2 câble de transmission souterrain
110kV Single Core High Voltage Cable 1000 mm2 600 mm2 3130 mm Underground Transmission Cable Application Power Transmission Systems: Primarily used in large-scale power grids to transmit electricity between power stations, substations, and urban distribution networks, especially for voltages above 110kV. Electric Vehicles (EVs): Transmit high-voltage electricity (up to 1500V) from batteries to motors, inverters, and charging systems, while also relaying signals to
N2XBY NA2XBY câble à basse tension à trois cœurs 0.6/1kV 0.5~800MM2 lV
N2XBY NA2XBY Low Voltage Cable 3 Core 0.6/1kV 0.5 ~ 800MM2 Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: XLPE Filler: non-hygroscopic material Binder tape: non-hygroscopic material Sheath: PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal operation:≤90℃. Max operating temperature of con. When cable short-circuited(5s
Cable électrique en cuivre en conserve flexible à câbles 2X12 AWG 2
Tinned Copper Flexible Stranded Electrical Wire 2X12 AWG 2 Core Cable APPLICATION Industrial equipment requiring high flexibility and durability, such as robotic arms and automated machinery. Power distribution systems where corrosion resistance is critical, especially in marine or humid environments Renewable energy installations (e.g., solar panel arrays) due to its excellent conductivity and tinned oxidation resistance. CONSTRUCTION AND SEPCIFICATION Conductor
Quadruplex Service Drop ABC Aerial Bundled Cables 3×70mm²+50mm² 3×95mm²+50mm²
Quadruplex Service Drop ABC Aerial Bundled Cables 3×70mm²+50mm² 3×95mm²+50mm² APPLICATION These cables are primarily used for three-phase power distribution from utility poles to residential/commercial service points, typically connecting pole-mounted transformers to weatherheads. The 3×70mm²+50mm² and 3×95mm²+50mm² configurations are designed for medium-to-high current loads, with the larger 95mm² variant supporting higher power demands. Key Applications: Residential
Cable d'alimentation photovoltaïque en alliage d'aluminium
Photovoltaic Aluminium Conductor Cable Aluminum Alloy 8000 Series Conductor Application Application Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC Construction Phase conductor: Aluminum alloy conductor 8000