pvc insulated cable
"
Câble blindé torsadé résistant au feu ZC-DJYPVP 300/500V pour instruments d'automatisation
Fire-resistant Pair Twisted Shielded Cable ZC-DJYPVP 300/500V for Automation Instruments APPLICATION The cables are mainly used in systems where signal transmission must continue working during a fire, especially for critical safety and control circuits. CONSTRUCTION C onductor: copper In s u lation: LLDPE Separate shielding: Braided shielding (P) O verall shield: Braided shielding (P) Armouring: Steel Tape Armour Outer sheath: Polyvinyl chloride ST2 (PVC) CHARA C TERISTIC 1.
XLPE câble conducteur en aluminium isolé fil d'acier en PVC blindé 8.7KV 15kV
8.7/15kV Aluminium Conductor Cable Steel Wire Armoured XLPE Insulated PVC Sheath Cable Application Distribution and signalling power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions requiring increased electric protection and protection against mechanical damages. Used in electric power plants, transformer stations, industrial plants, metropolitan networks
Cable blindé AWA à noyau unique à tension moyenne jusqu'à 36 kV pour les réseaux électriques urbains
Single Core AWA Armoured Cable Medium Voltage up to 36kV for Urban Power Grids APPLICATION Single Core AWA (Aluminium Wire Armoured) Medium Voltage Cable is engineered with a lightweight aluminium wire armour layer, delivering excellent mechanical protection, corrosion resistance and flexible installation performance. Designed for medium voltage systems typically ranging from 3.6/6 kV to 26/35 kV , it is widely deployed in the following critical scenarios: Urban power grids
Câble d'alimentation moyenne tension AAC conducteur en aluminium XLPE/PVC/STA 8.7 15kV
AAC Aluminium Conductor Cable XLPE/PVC/STA Medium Voltage Power Cable 8.7 15kV APPLICATION Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm ) Semi conductive tape+semi conductive shielding material (500 mm and above) Insulation: Polyvinyl chloride (PVC) Insulation
Câbles triplex UD ABC, câbles aériens en faisceaux ABC 19/33kV, câbles MT blindés selon IEC 60502
Triplex UD Cable ABC Aerial Bundled Cables 19/33kV Screened MV Cable to IEC 60502 APPLICATION Triplex UD Cable ABC Aerial Bundled Cables 19/33kV Screened cable is primarily used in overhead power distribution networks for transmitting electrical energy. It is designed for aerial installation and is suitable for medium-voltage applications (19kV to 33kV). The cable features a screened design to enhance electromagnetic compatibility and reduce interference. It is
Voltage moyen MV 26/35 KV câble d'alimentation en aluminium bande de cuivre bouclier en PVC
Medium Voltage 26/35 kV Aluminium Conductor Cable Copper Tape Shield PVC Sheath Application Medium-voltage aluminum alloy cables are used in power distribution and industrial systems where lightweight design, cost efficiency, and corrosion resistance are critical Key applications include: Urban/Suburban Grids : Overhead or underground power distribution (1–35 kV) for residential/commercial areas, reducing installation costs vs. copper. Industrial Power Networks :
0.6 KV 1KV câble résistant au feu sans halogène câble électrique extérieur intérieur
0.6/1KV Fireproof Insulation Fire Resistant Cable Indoor / Outdoor Electrical Cable Application It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Advantages - halogen-free, no
Cable conducteur en alliage d'aluminium souterrain de la série AA-8000 Longueur personnalisée
Underground Aluminum Alloy Conductor Cable AA-8000 Series YJLHV62 YJLHV22 Application The YJLHV62 YJLHV22 cable is an aluminum alloy conductor power cable designed for medium-voltage applications, combining durability, flexibility, and environmental resilience. Below is a detailed description: Construction Conductor{ Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm) Semi conductive tape+semi conductive shielding material (500 mm
IEC 60502 STA câble électrique blindé à trois cœurs pour utilisation souterraine
IEC 60502 STA Armoured Electrical Cable Three Core for underground use Application PVC power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions where heavier mechanical loads and specially tensile strains, are not expected. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants, same as for