logo
وجدت 433 منتجات لـ "

pvc insulated cable

"
الجودة كابل أداة مرن من البلاستيك المغطى المحمي المقاوم للبرد سلك نحاس متسلسل المصنع

كابل أداة مرن من البلاستيك المغطى المحمي المقاوم للبرد سلك نحاس متسلسل

Flexible PVC Sheathed Shielded Instrument Cable Cold-Resistant Stranded Copper Wire Application Shielded cables are suitable for flexible use with free movement, but without tensile stress or forced movements in dry wet and moist areas but are not suitable for open air application. These cables are ideal whenever construction requirements call for minimal outer diameter such as areas of tool making, machine industry, eletrotechnics, computers, measuring and controlling

الجودة كابل أجهزة حاسوب متعدد الأزواج المصنع

كابل أجهزة حاسوب متعدد الأزواج

Individual and Overall Shielded Instrument Cable Multi Pair Computer Cable APPLICATION The cable is suitable for electronic computers and automation instruments with high anti-interference requirements for rated voltage of 500V and below CONSTRUCTION C onductor: The first or second type of copper conductor In s u lation: Low density polyethylene (LLDPE) Fill er (optional): Filling rope Separate shielding: Braided shielding (P) O verall shield: Braided shielding (P) Outer

الجودة كابل ABC ثلاثي النواة + 1 أساسي بجهد 0.6/1 كيلوفولت - كابل ألومنيوم مجمع معزول بـ XLPE لخطوط الجهد المنخفض الهوائية المصنع

كابل ABC ثلاثي النواة + 1 أساسي بجهد 0.6/1 كيلوفولت - كابل ألومنيوم مجمع معزول بـ XLPE لخطوط الجهد المنخفض الهوائية

0.6/1kV 3+1 Core ABC Cable —XLPE Insulated Aluminium Aerial Bundled Cable for LV Overhead Lines Product Overview The 0.6/1kV 3+1 core ABC cable is designed for low voltage overhead power distribution systems. It consists of three phase conductors and one neutral conductor, all insulated with cross-linked polyethylene (XLPE) to ensure stable electrical performance and long service life. This cable structure improves operational safety and system reliability in overhead

الجودة شريط النحاس الدرع المتوسط الجهد السلاحي الكابل 6KV 10kV 600sq استخدام تحت الأرض المصنع

شريط النحاس الدرع المتوسط الجهد السلاحي الكابل 6KV 10kV 600sq استخدام تحت الأرض

Copper Tape Shield Medium Voltage 6/10kV Steel Tape Armoured 600sq Underground Use Construction Conductor: Circular compacted stranded Copper or aluminium Conductor screen: Extruded semi-conductive compound Insulation: XLPE Insulation screen: Extruded semi-conductive compound Metallic screen: Copper Wire Binder tape: non-hygroscopic material Inner covering(bedding): PVC Metallic armor: Galvanized steel tape Application Suitable for urban underground power grids, power station

الجودة كابل طاقة معزول XLPE مقاوم للحريق CU/XLPE/STA/PE لتطبيقات السلامة من الحرائق المصنع

كابل طاقة معزول XLPE مقاوم للحريق CU/XLPE/STA/PE لتطبيقات السلامة من الحرائق

Fire Resistant XLPE Insulated Power Cable CU/XLPE/STA/PE for Fire Safety Applications This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications This specialized power cable is designed for critical fire safety applications where reliable performance under extreme conditions is paramount. Its core application lies in ‌emergency power supply systems‌. Construction Details

الجودة كابل مقاوم للحريق منخفض الجهد 0.6/1kV مع موصل نحاس وعزل XLPE لتطبيقات السلامة من الحرائق المصنع

كابل مقاوم للحريق منخفض الجهد 0.6/1kV مع موصل نحاس وعزل XLPE لتطبيقات السلامة من الحرائق

Low Voltage Fire Rated Cable 0.6/1kV CU/XLPE/PE YJY N2X2Y This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications Suitable for installation in cable ducts, underground applications, and exposed installations in various industrial and commercial environments. Construction Details Conductor: Class 1/Class 2 stranded copper conductor Refractory layer: Single-sided gold mica tape

الجودة كابل مقاوم للحريق منخفض الجهد 0.6/1kV مع موصل نحاس وعزل XLPE لتطبيقات السلامة من الحرائق المصنع

كابل مقاوم للحريق منخفض الجهد 0.6/1kV مع موصل نحاس وعزل XLPE لتطبيقات السلامة من الحرائق

Low Voltage Fire Rated Cable 0.6/1kV CU/XLPE/PE YJY N2X2Y This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications Suitable for installation in cable ducts, underground applications, and exposed installations in various industrial and commercial environments. Construction Details Conductor: Class 1/Class 2 stranded copper conductor Refractory layer: Single-sided gold mica tape

الجودة كابل طاقة مدرع مضاد للنار CU/XLPE/AWA/SWA/PE لنقل الطاقة المصنع

كابل طاقة مدرع مضاد للنار CU/XLPE/AWA/SWA/PE لنقل الطاقة

Flame Retardant Armoured Power Cable CU/XLPE/AWA/SWA/PE for Power Transmission APPLICATION Flame Retardant Armoured Power Cable CU/XLPE/AWA/SWA/PE for Power Transmission‌ is a high-performance cable designed for safe and reliable power transmission in demanding environments CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler ( options ): Polypropylene mesh tear rope or flame-retardant filling

الجودة AWA SWA كابل مدرع نحاس 100m الطول كابل PVC مغطى المصنع

AWA SWA كابل مدرع نحاس 100m الطول كابل PVC مغطى

AWA SWA Armoured Electrical Cable Copper 100m Length PVC Sheathed Stranded Cable Application Power transmission and distribution system: Widely used in medium voltage power transmission and distribution lines of urban power grids, rural power grids, and industrial enterprises. It is used for transmitting and distributing electrical energy and can meet the power transmission needs of different voltage levels (such as 6/6kV - 26/35kV). Industrial field: In industrial places